SQL Server Management Studio Always On Availability Group Change Primary Listener
- Article ID:
4248 - Date Created
Thursday, May 5, 2022 - Last Updated
Thursday, May 5, 2022 - This Article Has been Viewed
484 times - Short Desc
This article will show you how to change the Primary Listener in SQL Server Management Studios Always On Availability Group. - Details
This article will show how to perform a failover within the Always On Availability Group (AOAG). This is required with performing maintenance or if a SQL Server instance is having an issue, and you want to take it offline before it causes significant problems without your AOAG. - Recreate Issue
In our network, we have a maintenance server that we failover too when we take down our primary server, a [Dell r710]. The maintenance server's SQL Server instance is a part of the SQL Server AOAG. Since this SQL Server is a part of the AOAG, we can stay online without showing a maintenance banner in place of our websites.
The maintenance server has nowhere near the power of the [Dell r710]; it does the job we need to stay online while making our servers better for our future. - Resolve Issue
The built-in Wizard to failover to a new SQL Server primary is more straightforward than the standard method.
The method described below allows for a quicker and simpler failover transition.
In SSMS, expand the SQL Server Listener Server. Example: [MyAOAGListener,2433]
Right-click [Always On High Availability]
Choose [Show dashboard]
When the Dashboard opens, on the top list of [Availability replica:]
Click on the SQL Server Instance to failover too.
Once the page opens, from the top left side.
Choose [Start Failover Wizard]
This method will only have the chosen server selected and available for the failover.
Follow the wizard to failover the chosen SQL Server instance.
Share With Friends (Updated 6-8-2010)
Recent Articles
All Topics
- Coming Soon - Knowledge Exchange
Trending Articles
- Microsoft VBScript runtime error '800a0046' Permission denied FileSystemObject 24694
- Microsoft OLE DB Provider for SQL Server error '80040e57' String or binary data would be truncated. or The field is too small to accept the amount of data you attempted to add. Try inserting or pasting less data. 21297
- ADODB.Parameters error '800a0e7c' Parameter object is improperly defined 19544
- After Effects warning: Audio conforming failed for the following file .cfa. Perhaps due to disk space 17785
- The backup set holds a backup of a database other than the existing 16825